AnsweredAssumed Answered

How can I open Part Editor in read/write mode from the GUI after using a script to access it?

Question asked by A.Ozenne on Jun 10, 2011
Latest reply on Jun 10, 2011 by A.Ozenne

Hello,

 

I am trying to use automation for library management and part creation. I am currently working on pin mapping so I am accessing the Part Editor through automation. I can access the data with my script but then, when I go back to the GUI and try to modify some parts, I get the following message when I open the Part Editor:

 

Opening "SomePartPartition" read only because it is already reserved by "MyName@MyMachine:Part Editor:".

 

It looks like there is a lock somewhere. I tried the following simple script to try to close correctly the PartEditor but I still get the message above:

 

Option Explicit

 

Dim objPartEditor

Set objPartEditor = CreateObject("MGCPCBLibraries.PartsEditorDlg")

Scripting.AddTypeLibrary("MGCPCBLibraries.PartsEditorDlg")

 

Dim dbFile

dbFile = "C:\Path\to\my\library.lmc"

 

Dim pdbDB

Set pdbDB = objPartEditor.OpenDatabaseEx(dbFile, False)

 

objPartEditor.LockServer()

objPartEditor.UnlockServer()

objPartEditor.Quit()

 

 

Set objPartEditor = Nothing

 

Do any of you have an idea how to get back read/write access from the GUI?

 

Thank you.

 

Anthony