thomas.te.ebert

Model Mix of HSPICE and IBIS on Virtex-5 SI-Simulation Kit

Discussion created by thomas.te.ebert on Aug 18, 2011
Latest reply on Oct 9, 2013 by saddam.sarwar786

I'm trying actually to mix on a SERDES simulation the HSPICE model of Virtex-5 GTP transceiver with an IBIS receiver from National Instruments.

The simulation is based on the eye diagram. The result will be that the voltage level will be rising up to +/-2000V.

 

When I simulte purely with the HSPICE (transceiver/receiver from Xilinx) models or IBIS (transceiver/receiver from NI) models I got the eye diagram as the result.

 

What I'm doing wrongly?

 

Thanks and Best Regards

Thomas